vacuum value without nozzle
Jan 03, 2022 Editor: admin
This menu command allows you to set vacuum value of each head on which no nozzle is mounted.This setting causes the system to check a deviation of the cacuum values of heads. If the value changes greatly by comparing with the value set at delivery of the machine (by about 10%), check and clean each head.
When you select the <Vacuum value without nozzle> command, the following "Vacuum value without nozzle" dialog box appears on the screen.
Vacuum value without nozzle | ||
L-Head(LNC60) | R-Head (CDS) | |
Nozzle1 | -44.694kpa | Nozzle1 -46.184kpa |
Nozzle2 | -42.211kpa | |
Nozzle3 | -42.708kpa | |
Nozzle4 | -45.191kpa | |
Nozzle5 | -47.674kpa | |
Nozzle6 | -43.204kpa |
Select a head, and click the <Exec> button. The system automatically obtains its vacuum valve.
After setting the vacuum value, click the <OK> button. The set value is validated.
Warning: When you click the <Exec> button, the axes move and the nozzle is attached or removed. Before clicking the <Exec> button, be sure to check to see if there is no one who operate the inside of the machine. To avoid a risk of injury, do not place your hand in the machine, nor move your face or head close to the machine.