Mechanical Specifications
Mar 15, 2022 Editor: admin
1 placement accuracySquare chip: +-0.05 mm
For details of component placement accuracy, refer to chapter 5 in the instruction manual of the supplied CD.
2, Number of ATC nozzle stocks
Number of ATCs: 4 units(two on the front+two on the rear)
Number of stocked nozzles: 10/1 unit
3, PWBs transport heights
900+-20mm (for domestic, china and southeast Asian countries)
950+-20mm (for europe and the USA)
4, Machine dimensions and mass
Approximately 2000KG
5, Air requirements
Air pressure : 0.49+- Mpa Dry air
atmospheric pressure dew point= 17degree or lower
Maximum air consumption: 400L/min(standard condition)
6, Noise Level
76dB (A) or less.
7, Environmental conditions
Use enviroment conditions
Temperature: Ambient temperature +10 degree to +35 degree
The accuracy guranteed ambient temperature range depends on the descriptions in item "mounting accuracy"
Humidity: 50% RH or lower (at 35 degree)
Strage environment conditions
Temperature: -15degree to +70 degree
Humidity: 20% to 95% RH
8 Electric specifications
Voltage | 3-phase AC 200V 220V 240V 380V 400V 425V |
Frequency | 50/60Hz | Maximum rated apparent power | 12-kVA |
Voltage cariation tolerance | +-10% | Primary side power supply cable size | 6mm or higher |