FBT10
|
1 |
Instrument model |
FBT10 |
|
2 |
Overall Dimension |
20*47*148(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
10 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT12
|
1 |
Instrument model |
FBT12 |
|
2 |
Overall Dimension |
20*47*179(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
12 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT24
|
1 |
Instrument model |
FBT24 |
|
2 |
Overall Dimension |
20*94*155mm (H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
24 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT60
|
1 |
Instrument model |
FBT60 |
|
2 |
Overall Dimension |
12*47*203(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
6 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT61
|
1 |
Instrument model |
FBT61 |
|
2 |
Overall Dimension |
20*47*148(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
6 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT62
|
1 |
Instrument model |
FBT62 |
|
2 |
Overall Dimension |
20*53*120(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
6 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
FBT80
|
1 |
Instrument model |
FBT80 |
|
2 |
Overall Dimension |
20*47*148(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.01 times/ per second ~ once per hour |
|
6 |
dedicated space |
16M(optional) |
|
7 |
channel number |
8 |
|
8 |
Storage group number |
255(optional) |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger, communication trigger |
|
12 |
Instrument operating temperature |
-40~+105℃ |
|
13 |
Temperature Range |
-200~+1370℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
32 |
V6
|
1 |
Instrument model |
V6 |
|
2 |
Overall Dimension |
20*53*100(mm)(H*W*L) |
|
3 |
certainty of measurement |
+/-0.5℃ |
|
4 |
temperature resolution |
0.1℃ |
|
5 |
frequency of sampling |
0.1 times/ per second ~ once per hour |
|
6 |
dedicated space |
4M |
|
7 |
channel number |
6 |
|
8 |
Storage group number |
10 |
|
9 |
battery capacity |
1200MA |
|
10 |
starting mode |
Key trigger, temperature trigger, delay trigger |
|
11 |
stop mode |
Key trigger, temperature trigger, delay trigger |
|
12 |
Instrument operating temperature |
-40~+85℃ |
|
13 |
Temperature Range |
0~+500℃ |
|
14 |
Thermocouple type |
Type K |
|
15 |
Processor bits |
8 |